Icea method 1 uses solid colors with longitudinal or spiral stripes in accordance with icea standard s73532 table e2 icea method 3 uses solid colors with printed numbers and colors per icea standard s73532 table e4 icea method 4 black insulation with printed color code per icea standard s73532 table e4. Browse color coding charts icea method 1 and 2, table e1 and e2 in the american wire group catalog including 800. Ansinema wc 572014icea s735322014 standard for control, thermocouple extension, and instrumentation cables 2014 price. Section 1605 buy american compliant i certify that the above listed material complies with requirements including applicable standards set forth in this certification. If looking for a cable standard, consider specifying nema wc 57 ansi icea s 73 532 standard for control, thermocouple extension and instrumentation cables. Find the most uptodate version of icea s73532 at engineering360. The cable standards set by nema is applicable to shielded and nonshielded power cables for the distribution of electric energy as well as lan communication wiring systems and various test methods. Ansinema wc 74 icea s 936392017 applies to materials, constructions and testing of 5,000 v to 46,000 v shielded crosslinked polyethylene, and ethylene propylene rubber insulated wires and cables used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground or submarine. Applies to materials, constructions, and testing of 2000 volts and less thermoplastic, crosslinked polyethylene, and crosslinked rubber insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions of.
In earlier documents they were located in appendix k. Some people think that instrument cables are power limited cables. Our website provide pdf immediately download,sometimes when you purchased cant online download please contact us,we will send the document to you with email. Applies to materials, constructions and testing of 2001 through 5000 v nonshielded power cables having insulations of crosslinked polyethylene includes both crosslinked and treeretardant crosslinked polyethylene or crosslinked rubber of the types shown in section 4. Applies to materials, constructions, and testing of 5,000 v to 46,000 v shielded crosslinked polyethylene, and ethylene propylene rubber insulated wires and cables that are used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground, or submarine. Icea and approved by the national electrical manufacturers association nema. Electric power connection for substations standard by american national standards institute national electrical manufacturers association, 01012005. Ansinema wc 74icea s936392017 applies to materials, constructions and testing of 5,000 v to 46,000 v shielded crosslinked polyethylene, and ethylene propylene rubber insulated wires and cables used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground or submarine. Ansinema wc 70icea s95658 nonshielded power cables.
The standard for control, thermocouple extension and instrumentation cables, icea s 73 532, nema wc 572003, was developed by the insulated cable engineers association, inc. Pdfacrobat reader or word version doc document file. The two most common sequences are in tables 1 and 2 of appendix e of the icea nema standard and are therefore referred as e1 and e2. Section 1605 buy american compliant nema wc70icea s95658 construction.
Icea s58679 control cable conductor identification method 1 table 2. The cable standards set by nema is applicable to shielded and nonshielded power cables for the distribution of electric energy as well as lan communication wiring systems and. Inner jackets for multiconductor cables may be colorcoded as well reference table e1, table e2, and table e3 of nema wc 572004 icea s 73 532 b96 for guidance. Ansinema wc 572014 icea s 73 532 2014 standard for control, thermocouple extension, and instrumentation cables 2014 price. Conductor printing details conductor printing details 1st 1one1 4th 4four4 2nd 2two2 5th 5five5 3rd 3three3 6th 6six6 per icea s73532e3. Ansinema wc 57 2014icea s735322014 standard for control, thermocouple extension, and instrumentation cables. Bare, softannealed stranded copper conductors per astmb787 and ul83 insulation. Icea s66524 copyright licensed by national electrical manufacturers association i. It is important to note that in earlier editions of the icea s73532 nema wc 57 the color sequences were located in appendix k and were referred to as k1 and k2. Nema wc 571995icea s73532 standard for control cables.
Ieee 1202 ft4 vertical tray flame test 70,000 btuhr and icea t29520. The national electrical manufacturers association nema published ansinema wc 57icea s735322014 american national standard for control, thermocouple extension, and instrumentation cables. Color coding charts icea method 1 and 2, table e1 and e2. The most common standard used for control cables is icea insulated cable engineers association standard s73532, nema national electrical manufacturers association standard wc57, standard for control, thermocouple extension, and instrumentation cable. Icea s73532 standard for control, thermocouple extension and instrumentation cables. Methods for identification of control cable conductors by number with base and tracer colors on each conductor are discussed in appendix e of nema wc 572004 icea s 73 532 b96. Control cable, multiconductor, 600 v standard number. Icea s73532 and nema wc57 for control applications.
Armored options available free catalogue information download icea s 665241991 crosslinked. Older wire and cable specs may reference k1 or k2 color codes, but they are the. Ansinema wc 572014icea s735322014 standard for control thermocouple extension, and instrumentation cables ansinema wc 66icea s1167322019 standard for category 6 and 6a, 100 ohm, individually unshielded twisted pairs, indoor cables with or without an overall shield for use in lan communication wiring systems. Multiconductor cu 600v xlpe xhhw2 pvc control cable. Small diameter control, reel and pendant, sdn ul type tc. Ansinema wc 57 2014icea s735322014 standard for control thermocouple extension, and instrumentation cables. Nema wc 57icea 573532 ul 1685ft4ieee 1202 70,000 btuhr flame test icea t29520 210,000 btuhr flame test arra 2009. Outline existing nemaicea and ansiicea standards proposed changes to standards new ansiicea and. This standard describes different methods of identification and provides tables of color sequences to use. Methods for identification of control cable conductors by number with base and tracer colors on each conductor are discussed in appendix e of nema wc 572004icea s73532 b96. Icea s 73 532 and nema wc57 for control applications. Base color tracer 1 black 19 orange blue 2 red 20 yellow blue 3 blue 21 brown blue 4 orange 22 black orange 5 yellow 23 red orange 6 brown 24 blue orange 7 red black 25 yellow orange 8 blue black 26 brown orange 9 orange black 27 black yellow 10 yellow black 28 red yellow. The national electrical manufacturers association nema published ansinema wc 57 icea s 73 532 2014 american national standard for control, thermocouple extension, and instrumentation cables. Applies to materials, constructions, and testing of 2000 volts and less thermoplastic, crosslinked polyethylene, and crosslinked rubber insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions.
Ansinema wc 572014icea s735322014 standard for control. It is important to note that in earlier editions of the icea s 73 532 nema wc 57 the color sequences were located in appendix k and were referred to as k1 and k2. Armored options available free catalogue information download icea s665241991 crosslinked. Ansinemaicea cable standards set ansinemaicea cable standards set. Instrumentation and portable cables for testansinema wc 572004icea s73532 standard for control, thermocouple extension and instrumentation cablesansiies rp1605 nomenclature and definitions for illuminating engineering, includes addendum 2008ansinema c29. Nema wc 571995icea s73532 standard for control cables nema wc 581997icea s75381 portable and power feeder cables for use in mines. This standard applies to materials, construction, and testing of multiconductor control, thermocouple extension, and instrumentation cables rated up to and including 125oc. Standard for control, thermocouple extension and instrumentation cables ansinema wc 572004icea s73532. National electrical manufacturers association nema price. Rohs compliant tcer rating applies to cables with 3 or more insulated conductors. Pdfacrobat reader or word version doc document file size. Methods each conductor identification method has been assigned a reference number by. Icea s 66524 copyright licensed by national electrical manufacturers association i.
Low coefficient of friction makes installation easier. Find the most uptodate version of icea s 73 532 at engineering360. Icea s95658 nema wc70 power cables rated 2000 volts or less for the distribution of electrical energy. Ansinema wc 57 2004icea s73532 standard for control, thermocouple extension and instrumentation cables national electrical manufacturers association 20dec2004 82 pages. Color coding charts icea method 1 and 2, table e1 and e. Inner jackets for multiconductor cables may be colorcoded as well reference table e1, table e2, and table e3 of nema wc 572004icea s73532 b96 for guidance. Ansinema wc 70icea s95658 nonshielded power cables rated 2000 volts or less for the distribution of electrical energy. Standard for control, thermocouple extension and instrumentation cables ansinema wc 572004icea s73532 the association of electrical equipment and medical imaging manufacturers on. Excellent electrical properties, chemical resistance, resistance to fluids, and flame resistance. Icea method 1 uses solid colors with longitudinal or spiral stripes in accordance with icea standard s 73 532 table e2 icea method 3 uses solid colors with printed numbers and colors per icea standard s 73 532 table e4 icea method 4 black insulation with printed color code per icea standard s 73 532 table e4.